OpenAir Source: How to modify the InputType parameter dynamically at runtime
The InputType parameter is available in the data flow properties
list. Follow these steps to set up an expression:
- Create a variable that can be loaded with the desired InputType.
- Right-click on the data flow canvas and select
the Properties menu.
- Scroll down and find the properties in the group
called Misc.
- Note the name of the property you want to modify
dynamically at runtime. It will be named something like this: [OpenAir Source].[InputType].
This is the property containing
the InputType.
- Scroll down and find the Expressions property.
Set up an expression for the property noted above using a variable to
modify it dynamically at runtime.